Work InstructionsStandard Work InstructionsGo / No Go gauges:Fully clean the clamp plate and follow the below SWI steps to determine whether it is reusable,repairable or junkStepInstructions1Examine the four facesof the hinges in theclamp plate (see figure1). If any amount ofwear is seen, measurethe distance betweenthe hinges to ensurethat they are notexceedingly worn out.Refer to step 2 on howto measure the distancebetween the hinges andnoting the maximumwear limit.PicturesFigure 1If you notice gougingor pitting remove thebushings and segregatethe clamp plate forrepair (figure2).Lug wear: if the weardoes not reach the lugbore send it for repair(see figure 3).Figure 2Figure 32Use go /no-go gauge #103119232 (475) and/or103119246 (675) tomeasure the distancesbetween the hinges onthe clamp plate. Sideput the gauge androtate; insert one endand attempt to rotate thegauge around. If thegauge does not fit, thenreuse the clamp plate; ifit fits, then the clampplate will need to berepaired.The maximum lugdistance are as follows:1- 675: 33.10mm2- 475: 28.40mmGauge does not fit goodGauge does fit bad34Examine the t ...